狠狠色丁香九九婷婷综合丨一级片特黄丨韩国三级hd中文字幕叫床丨五月天精品丨日本成熟视频免费视频丨国产乱子伦60女人的皮视频丨亚洲xx网站丨国产亚洲精品久久久久蜜臀丨男女羞羞羞视频午夜视频丨亚洲天堂2015丨亚洲精品成人av在线观看爽翻天丨日韩午夜免费丨国产成人在线综合丨国产 成人 综合 亚洲 网站丨九九久久久丨艳妇荡乳豪妇荡乳av精东丨天堂av免费看丨黄网址在线观看丨日韩一级黄丨黄色av网址大全

[Factors of freezing cracking of copper pipe of central air conditioning chiller]
Release date:[2024/6/27] Is reading[399]次

Central air conditioning water cooling unit is a large air conditioning system component using water as a cold and heat exchange medium, mainly used in commercial buildings, hospitals, factories, office buildings, hotels and other places requiring large area temperature control. The working principle of this type of unit is to generate cold water or hot water through the outdoor host, and then with the circulation of the pump to transport these cold/hot water to the indoor end equipment (such as fan coil, air treatment unit, etc.), in the end equipment, cold/hot water and indoor air heat exchange, so as to achieve the indoor environment of cooling or heating.


The main reasons for freezing crack of copper pipe of central air conditioning chiller:


1, operation error and pressure control system failure: the operator's error may lead to improper setting of system parameters, such as the evaporation pressure is too low and not adjusted in time or the pressure controller failure fails to automatically shut down when the pressure is abnormal, which will lead to the temperature in the evaporator is too low, which may freeze the frozen water, cause physical damage to the copper pipe, and eventually lead to freezing.


2, copper tube material or manufacturing defects: if the evaporator copper tube itself has quality problems, such as insufficient material purity, manufacturing process defects, etc., these may reduce the pressure bearing capacity and corrosion resistance of the copper tube, so that the copper tube gradually weakens in long-term operation, and finally breaks due to unable to withstand normal working pressure or slight frost swelling stress.


3, the evaporation pressure is too low and too cold phenomenon: when the evaporation pressure of the evaporator is too low, it means that the evaporation temperature is far lower than the design value, which will lead to excessive cooling and even freezing of frozen water. The volume of ice is greater than that of water, which will form an expansive force inside the copper pipe and directly act on the wall of the copper pipe, causing physical damage, and in serious cases, it will lead to freezing and cracking of the copper pipe.


4, insufficient maintenance and protection mechanism failure: regular maintenance is essential to ensure the normal operation of the chiller. Lack of proper maintenance will cause the surface of the heat exchanger to accumulate dirt, affect the heat exchange efficiency, resulting in local supercooling. At the same time, if the safety control system such as freezing point protection and pressure protection fails to start in time due to failure or improper calibration, it will not be able to automatically stop the operation of the unit before the occurrence of dangerous situations, which may lead to copper pipe freezing cracking accidents from a single point to a large area.


Declaration: The content and template of this article are organized from the network, and the copyright belongs to the original author; If there is infringement, please inform in time and contact to delete.

Keyword:
ADD:No. 18, Rongguang Road, National High-tech Park, Yancheng City, Jiangsu Province Phone: 0086-13705113637 Tell: 0086-0515-88809180 Fax: 0086-0515-88809181 E-Mail: jsjckt@126.com
Copyright ? 2018 All rights reserved
Copyright Jiangsu Jin Cheng Air Conditioning Engineering Co.,Ltd 技術支持:中國丙綸網